Showing posts with label AcqKnowledge. Show all posts

Wireless │ Children’s Behavioral Inhibition

Shy child hiding behind parent because of behavioral inhibition
Behavioral inhibition (BI) has proven to be a fundamental risk factor in childhood anxiety psychopathology, arguably the most crucial factor in the development of anxiety. BI is defined as the increased arousal in response to novel stimuli, shyness, and withdrawal even in high-reward situations. The strength of this association varies based on respiratory sinus arrhythmia (RSA) regulation, yet little is known about this function in children with anxiety disorders.

RSA is characterized as the rhythmic fluctuations in heart rate associated with the respiratory cycle regulated by the parasympathetic nervous system. In a “basal,” or low-threat situation, RSA slows down the heart to maintain baseline levels. In a “challenge,” or high-threat situation, RSA is suppressed, which results in an increased heart rate and a fight-or-flight response. Thus, a greater control of the parasympathetic nervous system corresponds with high basal RSA (slowed heart rate) and increased adaptability and composure during threatening situations.

In “Children's behavioral inhibition and anxiety disorder symptom severity: The role of individual differences in respiratory sinus arrhythmia ,” an original research article in tech science journal , Behaviour Research and Therapy, Viana, Andres G., et al. explored the ability of RSA to moderate the association between BI and anxiety disorder symptom severity. They investigated RSA response during both a basal situation and challenge situation in the context of clinical anxiety. Participants consisted of forty-four children between the ages of 8 and 12, and their mothers. The first session involved self-report questionnaires and clinical interviews, and the second session involved an experiment with the children in a challenge situation. Using a BIOPAC MP system, the researchers gathered electrocardiogram (ECG) data with a wireless BioNomadix ECG transmitter and receiver. They also measured changes in the subjects’ thoracic circumference with the wireless BioNomadix respiration transducer, and recorded online through AcqKnowledge.

The data collected were analyzed to find RSA mean scores and revealed a positive association between BI and anxiety disorder symptom severity. Children with high levels of BI and low RSA responses to basal and challenge situations were found to have the highest levels of anxiety disorder symptoms. In addition, among children with high RSA responses to basal and challenge situations, the association with BI was non-significant. These findings support the supposition that higher levels of RSA, and ability to control the parasympathetic nervous system, may function to weaken the relationship between BI and anxiety. Thus, higher RSA may be related to an increased ability to regulate psycho-physiological responses and emotion, and act as a buffer against psychopathology.

Wireless | Emotional Regulation

Wouldn’t it be nice to be able to regulate your emotional reactions? Birk and Bonanno (2016) studied the adaptiveness of modifying emotional regulation (ER) strategies based on affective and physiological feedback. They wanted to understand how people use emotional regulation to adjust from thinking about emotional situation to more neutral information (distraction). To develop a more coherent comprehensive understanding, researchers studied whether people use internal feedback (negative intensity, corrugator’s activity, heart rate) to guide emotional regulation. Birk and Bonanno performed two studies: Study 1 examined switching from reappraisal to distraction and Study 2 examined switching from distraction to reappraisal. The studies explored whether internal feedback influenced people to shift to an optimal strategy (distraction), instead of a nonoptimal (reappraisal) strategy, when regulating strong emotional reactions. In addition, both researchers tested whether the frequency of switching and response to internal feedback (RIF) predicted well-being. The researchers found that negative intensity, corrugator’s activity, and the magnitude of heart rate deceleration were higher on switching rather than maintained strategies. In Study 1, researchers found that a greater switching frequency showed higher rates of higher and lower life satisfaction. Birk and Bonanno were able to record and analyze data using a BIOPAC Research System with wireless BioNomadix and AcqKnowledge software. Facial electromyography, electrocardiography, and electrodermal activity were the physiological signals measured. Wireless BioNomadix data recording allows researchers to assess ambulatory subjects in an environment most appropriate for their study. BioNomadix amplifiers are capable of interfacing with MP Systems and AcqKnowledge software for a complete, wireless solution that supports advanced analysis for multiple applications. In conclusion, Birk and Bonanno collectively found that internal feedback about the experience of intense negative emotion guides the decision to switch form reappraisal to distraction in Study 1, but not the reverse order of strategies in Study 2.

Wireless | Emotion Processing in Schizophrenia

Schizophrenia has long been known to be a very complicated and poorly understood cognitive disorder. To attempt to understand the differences in emotional processing in schizophrenic patients, psychologists use physiological parameters to quantify psychological activity. Researchers Peterman et al. performed a study in which Galvanic Skin Response (GSR or EDA) and Facial Electromyography (fEMG) were recorded in schizophrenic and control subjects in response to social stimuli to assess the differences in adaptive emotional response. To measure these signals, they used wireless BIOPAC BioNomadix amplifiers, one for GSR (BN-PPGED) and two for fEMG (BN-EMG2). The participants were asked to view a block of images of the same category (e.g., social positive, non-social negative, etc.), then select a positivity response (valence rating) as to how they felt about the images. Subjects viewed several blocks of images to evoke differing responses. The self-reported valence ratings were paired to physiological data acquired with wireless BioNomadix transmitters. The GSR and fEMG were collected with an MP150 data acquisition system, and the data was analyzed with AcqKnowledge software. Researchers found that the Schizophrenic subjects responded similarly to the controls in the valence ratings, but their GSR and fEMG data diverged significantly. The Schizophrenic subjects showed a stronger overall GSR response to the images; however they did not show an effect by the sociality of the pictures. The fEMG response was also greater overall in the Schizophrenic group, but also did not vary by sociality. The results provide physiological background to the disrupted self-awareness of emotion processing in Schizophrenics. The complexity of emotion processing in cognitive disorders continues to elude us and to pave new avenues for scientific study. Along with the BioNomadix modules used in the study, BIOPAC Systems offers several wireless, wearable physiological data acquisition and analysis systems for psychophysiological research.




Wearable/Wireless | 3D Seismocardiography

ECG CardiologyResearchers have been investigating the use of a promising, yet not entirely understood technique known as seismocardiography. This method takes advantage of natural vibrations produced by the cardiovascular system by recording with accelerometers, and using obtained data to make inferences about the state of health of the subject. Its use has shown promise as a noninvasive technique to measure heart health in both clinical and ambulatory environments. Researchers Paukkunen et al. have recently studied the three-dimensional vibration patterns of the cardiovascular system in an attempt to quantify them and make connections to the health of their subjects. To supplement their data, the researchers used a BIOPAC ECG amplifier and wireless respiration transducer to gain insight into the cardiovascular health of participants. Data was collected and analyzed from both a group of healthy subjects as well as a group of those affected by atrial flutter.  The accelerometer and ECG/Respiration data was analyzed with AcqKnowledge, in an effort to understand more about the 3D vibration patterns and their use as indicators for disease. What the researchers found was that the data did differ significantly between the healthy subjects and those with heart flutter. How the data differed was in the relative location of these vibration events occurring in different parts of the cardiovascular system. By comparing to consistent cardiology data, the researchers were able to produce results that suggested that spatial distribution of seismocardiographic events. BIOPAC Systems offers these solutions and others for cardiology, with products designed for reliable, consistent data acquisition and analysis for wireless and wearable use in a variety of environments. This research sets the stage for further investigation into the potential use of seismocardiography to catch signs of heart disease easily and affordably, providing a new weapon for our long-lasting battle for cardiovascular health.

Wireless, Wearable | Quality of Life Technologies

There is a major concern growing in the medical community that the ratio of health workers to population size is decreasing. This means that the number of available doctors and medical professionals is starting to become too small to handle the number of people needing medical help. Technologies are therefore being created to help bridge the gap that is being created. These “Quality of Life Technologies” (QoLTs) have been developed to help monitor the health of people. While these technologies have been able to provide physiological support to individuals, the same could not be said for mental symptoms. If QoLTs could move into the realm of psychology and self-therapy, they could help improve the mood and quality of life for patients. A group of researchers from the Polytechnic University of Bucharest and the University of Lincoln recently published a paper that presents a machine learning approach for stress detection using wearable physiological amplifiers. To induce stress in participants, the researchers had them perform both a public speaking and cognitive task, which according to previous research these tasks caused the highest increase in measurable signals.

For their experimental setup, they used a BIOPAC BioNomadix BN-PPGED wireless transducer, hooked up to an MP150 data acquisition system, to record both EDA and PPG signals. They then used AcqKnowledge 4 software to extract both the PPG autocorrelation signal and Heart Rate Variability (HRV). Their results provided accurate stress detection in individuals. Their analysis marks a good starting point toward real-time mood detection, which could lead to people improving their quality of life. One way they could improve their experimental setup however, would be to use the BioNomadix Logger. This device allows for up to 24 hours of high quality data logging allowing the researchers to analyze a subject’s data from when they encountered stressful situations outside the lab.


Data Logging | Understanding Social Fear Learning

Social fear learning seems like a fairly straightforward subject. A person observes another reacting or expressing through either verbal or nonverbal cues that a stimulus makes them fearful or afraid. Surprisingly though, little is known about how individuals modulate their perception of the threat. Researchers hypothesized that understanding and shared emotional experiences with others (empathy) play key roles in this, but there are a few investigations that support it. Thus Andreas Olsson, Kibby McMahon, Goran Papenberg, Jamil Zak, Niall Bolger, & Kevin N. Ochsner sought to study the role that empathy plays in social fear learning. The experiment was set up across two stages; one that tested manipulating empathy appraisals and the other individual variability of trait empathy. Researchers enlisted a final sample of 47 men and 53 women who attended Columbia University. The first stage had participants receiving standard instructions that enhanced or decreased empathy and underwent a fear learning procedure; the second had individuals undergoing two observational learning procedures seeing whether the participants expected to undergo the same learning as a demonstrator. During the test stage, conditioned fear response was assessed through skin conductance response (SCR) which was recorded from a BIOPAC MP150 system with an EDA100C amplifier that monitors SCL and SCR data—BioNomadix wireless EDA or Data Logger with EDA transmitter are viable setup alternatives. SCR waveforms were analyzed with AcqKnowledge software for off-line analysis. The study found that subjects enhancing their empathy had the strongest vicarious fear learning over the other groups. The results showed that—especially in the strongly empathetic groups—a demonstrator’s expression during the experiment tasks could serve as social unconditioned stimuli for individuals to vicariously learn fear. Social fear learning thus depends on both a person’s empathetic appraisal and their stable traits. Thus an individual’s ability to learn fear from a social situation comes from not only their inherent emotional state but also from their appraisal of how others around them are reacting to the social stimuli.

 


Logging Physiological Data | Data Acquisition

data acquisition hardware
Logging subject data has never been easier than with the advent of wireless subject recording devices. Quality wireless products allow for accurate readings on a subject’s physiology in ways tethered devices cannot. Now with products like the Mobita wearable biopotential system, data logging is simpler than ever before. Mobita is a physiological signal amplifier system that can record up to 32 channels of high-fidelity wireless biopotential data, including ECG, EEG, EGG, EMG, and EOG data. The Mobita also contains an onboard accelerometer that allows for, along with AcqKnowledge’s Actigraphy feature, evaluation of a subject’s activity levels. 

Together with AcqKnowledge software, the system can be quickly configured to do the work of multiple systems without the added cost of multiple amplifiers. Simply disconnect one header and snap on a new configuration for a completely different application. The system has the option to either log data locally for later download or telemeter back to a computer running AcqKnowledge for real-time display. The Mobita can easily switch between either live or logged mode to suit your research protocol. Using the built-in WiFi telemetry allows for a wide range of mobile subject recordings. The system has flash disk recording for up to 16 GB allowing large chunks of data to be stored and kept for back-up. Mobita is also a very flexible, wearable system due to its technical power and small size. Don’t let the system’s small size and rechargeable battery power operation fool you—the Mobita has the power to record up to 32 channels at up to 2K s/s and is fully integrated with AcqKnowledge. The system features a rugged construction making it well suited for tough and demanding measurement situations. The Mobita system is sturdy, dustproof, and most importantly is kept safe in its waterproof enclosure. The Mobita is the premier wireless biopotential system that is uniquely suited for a variety of applications such as psychology, neuromarketing, sports, ambulatory testing, and many more. See Mobita Systems Biopotentials

EEG Data Acquisition

BIOPAC offers a wide range of tools for recording and analyzing human or animal EEG signals. Available hardware includes the EEG100C amplifier, which amplifies bioelectric potentials associated with neuronal activity of the brain and can be used to perform unipolar or bipolar EEG measurements. The amplifier output can be switched between normal EEG and alpha wave detection. The 0.005 Hz HP setting will support Slow Cortical Potential measurement in the EEG. The Alpha detection mode outputs a smoothed wave with a peak indicating maximal alpha activity (signal energy in the 8-13 Hz frequency range).

EEG can now also be recorded from an MRI using the EEG100C-MRI smart amplifier. Data recording is easier and final results are cleaner when using the smart amplifier to derive EEG signals during fMRI or MRI. The unit incorporates advance signal processing to remove spurious MRI artifacts from physiological data. The MRI version of the EEG100C can still be sampled at the same rate as the normal amplifier during recording. This is because the MRI related artifacts are removed from the source, thus still leaving a perfectly recorded EEG signal. 

The amplifier includes a number of helpful features that improve derived EEG signals. There is less sensitivity to electrode and transducer lead placement and improved gain selectability. The unit minimizes computer based real-time or post-processing signal processing for faster data analysis. Cleaner data is available as a real-time analog output for easy analysis. The EEG100C-MRI contains the same functionality as the normal amplifier with the added compatibility with MRI cable and filter sets. 

AcqKnowledge provides powerful EEG analysis solutions. Use AcqKnowledge software to automatically filter raw EEG signal for Alpha, Beta, Theta, and Gamma wave activity and provide full frequency analysis of the data. AcqKnowledge contains powerful EEG analysis that provides a fully automated, epoch driven, analysis of the signal. The software also will remove any EOG artifacts from the signals. 

BIOPAC also offers a suite of wireless EEG solutions for mobile data recording. The Mobita, BioNomadix, and B-Alert X10 units all provide powerful wireless recording alternatives for EEG. The hardware allows for recording of EEG ranging from a single channel to up to 32 channels of data. Combined with AcqKnowledge software, the BIOPAC range of EEG recording products encompasses any need for in-lab recording, real-world and MRI applications. Learn more at EEG Applications http://www.biopac.com/eeg-electroencephalography

Noninvasive Cardiac Output | Data Acquisition

Noninvasive Cardiac Output (NICO) measures can be determined by employing electrical bioimpedance (EBI) measurement techniques. Electrical bioimpedance is the characteristic impedance of a volume of tissue and fluid. For Cardiac Output measures, the relevant tissue includes the heart and the immediate surrounding volume of the thorax, and the relevant fluid is blood.
The electrical impedance of the thorax (Zt) can be thought of as composed of two impedance types:
  1. The base impedance (Zo) corresponding to non-time varying tissues, such as muscle, bone and fat. Zo is measured when the pulsatile volume is minimal.
  2. The delta impedance (dZ) corresponding to time-varying fluid volume (blood).
http://www.biopac.com/noninvasive-blood-pressure-amplifier-nibpZt drops with each pulsatile volume of blood ejected from the heart. dZ/dt is the magnitude of the largest impedance change during systole.
Noninvasive cardiac output amplifiers incorporate a precision high-frequency current source, which injects a very small (400 microamp rms) current through the measurement tissue volume defined by the placement of a set of current source electrodes. A separate set of monitoring electrodes measures the voltage developed across the tissue volume. Because the current is constant, the voltage measured is proportional to the characteristics of the biological impedance of the tissue volume.
BIOPAC data acquisition hardware for recording real-time Noninvasive Cardiac Output parameters include tethered amplifiers such as the NICO100C (or NICO100C-MRI for fMRI environments), EBI100C, or SS31L, or the wireless BioNomadix BN-NICO.
Hardware simultaneously measures impedance magnitude and phase, and may incorporate an internal derivative function to output dZ/dt simultaneously with Z; an AcqKnowledge calculation channel can also be used to determine dZ/dt. The internal derivative function inverts the polarity of the dZ/dt signal so that it displays a positive-going peak, coincident with negative slopes indicated in Z, as per academic research convention.
Disposable Ag/AgCl Paired Electrodes (EL500) are recommended for bioimpedance and cardiac output studies. Paired electrodes provide fixed spacing between the dual contacts and are pre-gelled with hypo-allergenic, wet liquid gel electrolyte (10% chloride salt); the gel cavity is situated between electrode and skin surfaces and helps reduce motion artifact.
The impact of movement artifacts on recorded data is a significant methodological concern in impedance cardiography; Ensemble Averaging tools in AcqKnowledge provide an automated strategy to remove these artifacts. Watch a demo now!

Data Hardware & Software Platforms

Data acquisition hardware and software requirements vary widely based on experiment protocol, classroom setup, field studies, etc. BIOPAC data acquisition hardware platforms support wired, wireless, and fMRI setups, for human or animal subjects, with powerful, intuitive data software for research and teaching applications. Use with a variety of amplifiers, stimulators, triggers, transducers, gas analysis modules, and/or electrodes to acquire life science signals, including ECG, EEG, EOG, EMG, EGG, EDA, Respiration, Pulse, Temperature, Impedance Cardiography, Force, Accelerometry, Goniometry, Dynamometry, Gyro, and more. Combine data hardware for multi-subject or multi-parameter protocols.

Research hardware platforms are fully-integrated with AcqKnowledge® data acquisition software, which provides automated routines for data scoring, measurement, and reporting, and can support multiple hardware units. Teaching platforms include Biopac Student Lab software with media-rich tutorial style guide lessons for specified objectives, plus active learning options for student-designed experiments and advanced analysis.

Wired (tethered) data acquisition hardware platforms include the MP150 and MP36R Research Systems. The MP150 16-channel system with universal amplifier provides high resolution (16 bit), high-speed acquisition (400 kHz aggregate) with16 analog inputs and two analog outputs, digital I/O lines (to automatically control other TTL level equipment), and online calculation channels. The MP36R 4-channel research system with built-in amplifiers provides four analog inputs and one analog output, I/O port for digital devices, calculation channels, trigger port, headphone jack, and electrode impedance checker. The MP36R supports software-controlled amplifiers and calculation channels.

Wireless data hardware includes options for live or logged data:
BioNomadix wireless, wearable physiology monitoring devices noninvasively record high-quality, full-bandwidth data while comfortably allowing subjects to move freely in natural indoor environments. Digital transmission and transducers placed close to the signal source provide excellent signal quality. Record up to 16 channels of BioNomadix data with a BIOPAC MP150 System—the system also works with multiple MP150 systems or third-party data acquisition hardware via an isolated power supply module. 

Mobita® 32-channel wearable wireless systems are ideal for biopotential applications that demand subject mobility and data logging. The Mobita EEG System uses water electrodes—no skin prep or gels required. Record live data into AcqKnowledge or log to an internal storage card for later upload into AcqKnowledge; modes are easily switched to suit specific protocols.

B-Alert X10® Wireless Systems provide nine channels of high fidelity EEG plus ECG, and data software for cognitive state metrics software is available. The stand-alone system easily interfaces with MP150 Research System to synchronize with other physiological data.

BioHarness® with AcqKnowledge is a lightweight, non-restrictive data logger and telemetry system to monitor, record, and analyze a variety of physiological parameters, including ECG, respiration, posture, and acceleration.

Stellar® Small Animal Telemetry Licenses with AcqKnowledge control wireless data acquisition from Stellar Implantable Telemetry Systems. The easy-to-configure Animal Scheduler works for a subset or complete group of conscious, unrestrained small animals for long term recordings. Multiple display modes can be viewed simultaneously, and signal conditioning tools (e.g., filtering and artifact removal) can be applied.


These and other BIOPAC data hardware and software solutions are used in thousands of labs worldwide and cited in thousands of publications. Learn more about research systems and teaching systems.

Biomechanics Transducers | Data Acquisition

Biomechanics data can include measures of force and motion of body position, posture, and joint movement over a wide range of static and dynamic conditions. Biomechanics measurements are meaningful for a wide variety of research applications, such as biomedical engineering, exercise physiology, sports training or rehab, and ergonomics (for characteristics of a specific work activity or environment). 

Biomechanics transducers include goniometers, torsiometers, and accelerometers. Transducers are unobtrusive and lightweight, and can be worn comfortably and undetected under clothing or attached to external equipment—leaving the subject to move freely in the normal environment.
Biomechanics transducers connect directly to the BIOPAC Acquisition Unit as part of an MP or BSL System. For a more complete physiological analysis, additional signals can be recorded (e.g., EMG, respiration, heart rate) and video data can be tightly-synchronized for a clear and detailed view of the biomechanics of a movement with the subject’s physiological data.



Goniometers incorporate gauge elements that measure bending strain along or around a particular axis and transform angular position into a proportional electrical signal. The gauge mechanism allows for accurate measurement of polycentric joints. As the joint moves through a determined angle, the relative linear distance between the two mounting positions will change. A telescopic endblock prevents the measuring element from becoming over-stretched or buckled as the limb moves. The bending strain is proportional to the sum total angular shift along the axis. Because the bending force is extremely small, the output signal is uniquely a proportional function of the angular shift.


Twin-axis goniometers measure rotation about two orthogonal planes simultaneously to record limb angular movement, such as adequate bending in the elbows or knees, unsafe rounding in the lower spine, wrist or ankle flexion/extension, abduction/adduction, radial/ulnar deviations, etc. Single-axis goniometers measure the angle in one plane only and are used to record digit joint movement of fingers, thumb or toes.
Torsiometers measure rotation about a single axis (e.g., forearm pronation/supination) to record angular twisting (as opposed to bending) of the torso, spine or neck.

Tri-Axial Accelerometers are high level output transducers that provide three outputs to measure acceleration along the X-, Y- and Z-axes simultaneously. To reliably record head tilt, place an accelerometer on the head. To measure accelerations when performing slow movements, such as walking and hand tremor, ±5 G accelerometers are optimal; ±50 G are more suitable for quick movements, such as swinging a tennis racket.
For applications where quick or rapid movements are involved, fit a “sock” bandage over the whole sensor and interconnect lead. For accurate results from long recordings, use double-sided adhesive between the endblocks and skin, and place single-sided adhesive tape over the top of the endblocks. No tape should come into contact with the spring. The connection lead should also be taped down near the sensor element.

Wireless Surface EMG Modules | Data Acquisition


Physiological data acquisition systems offer many options for recording surface EMG, needle EMG, and fine wire EMG. General muscle activity and fatigue can be determined by recording and analyzing surface EMG data from major muscle groups.

Recording facial EMG data is well-suited for startle response studies, neuromarketing applications, and psychophysiology research.  Wireless surface EMG modules offer solutions for freely moving subjects in ambulatory environments, real-world settings, and virtual reality paradigms. Combining surface EMG recording channels with other physiological data allows for display and automated analysis of muscle contraction simultaneously with other physiological events.

Correlate EMG activity with data from other sources including force plates, goniometers, and motion analysis equipment. Analysis software tools, including spike counting, muscle activation location, and frequency analysis allow for post-acquisition surface EMG data interpretation. Results of EMG recordings can be output as graph channels for easy data visualization, or can be in numerical format in summary tables or spreadsheets. Data can then be used for further statistical analysis. 

EMG Analysis | Biomechanics

Biomechanics research has never been easier thanks to powerful new data acquisition and analysis tools. Perform real-time calculations and post-data acquisition analysis on a variety of biomechanical and physiological data.

Simultaneously acquire up to 16 channels of biomechanics and/or gait-specific data. An example setup could incorporate two channels of heel/toe strike timing, ten channels of EMG signals, and four channels of goniometry data — however combinations are virtually endless. Record sit-and-reach tests, range of motion evaluations, muscle balance assessments and more.

Real-time event markers allow researchers to log important events in the data and also include comments that can be written during or post acquisition.


After recording, choose an automated analysis package to interpret and score the biomechanics data. For example, automated EMG analysis allows for a variety of automated functions including deriving integrated EMG, root mean square (RMS) EMG, locating muscle activation, full frequency and power analysis, and much more.

Electrocardiogram Signals | ECG Analysis

Electrocardiogram signals can be recorded from humans or animals wirelessly or via tethered amplifiers(BioNomadix). Analyzing changes in ECG rhythms can provide valuable insight into stress, arousal, and exercise research.  Automated ECG Analysis packages are available that provide a wide variety of automated ECG analysis options. 


To examine changes in the physical ECG complex during experimental protocols the Locate ECG Complex boundaries routine will locate and score the different parts of the ECG complex (P, Q, R, S, T intervals).  The routine can be tailored for human or animal ECG recordings. For human signals, the automated ECG complex boundaries routine can also measure and extract the ECG interval information to a spreadsheet file or text file. Another automated ECG analysis routine will help the user classify heartbeats as normal, PVC, or unknown. This provides a quick automated analysis tool to identify and mark irregular heartbeats.

For more in-depth studies, such as heart rate variability analysis there are also automated tools that can be used to simplify the reporting process. Automated HRV analysis routines can provide a variety of output options including frequency information, tachograms, and R-R interval tables.

Additional automated ECG analysis tools are also available to examine respiratory sinus arrhythmia, determine beat-by-beat heart rate, and more.


Neuromarketing Solutions | Data Acquisition

Neuromarketing
Neuromarketing solutions are available that allow you to examine physiological responses to products, environments, other stimuli or decision making tasks. Multiple physiological signals can be recorded and analyzed for Neuromarketing, including EEG. EEG analysis options allow for understanding of the subject's cognitive state for a variety of Neuromarketing tasks.  Gauging level of engagement, workload and drowsiness while performing tasks or participating in consumer test situations can provide valuable insight into product development and marketing. Neuromarketing solutions should be as unobtrusive as possible, allowing for wireless EEG and other physiological signals to be recorded and analyzed from mobile subjects. Whether subjects are in a lab or real-world environment, users should have the ability to stream physiological data live or record and log up to 32-channels of high-quality biopotential data.


neuromarketing
For some applications, long-term activity studies may be necessary. Solutions are available that allow users to monitor subjects in their home environment over multiple hours or days. For example, record ECG, EEG, Respiration, EMG, and GPS positioning data to look at overall activity levels and physiological responses to different Neuromarketing stimuli and daily activities that include product interactions.

Muscular Biofeedback | Surface EMG


Biofeedback is a form of self-regulation in which an individual is provided information in the form of sensory feedback about a biological condition or function in order to gain control over that biological function. Biofeedback is often used as a therapeutic tool by which sports medicine/rehabilitation professionals, neurophysiologists, psychophysiologists, and therapists can use electrophysiological instrumentation to measure, process, and “feedback” the recorded information to the participating athlete or subject. The feedback is usually provided through auditory and/or visual means.



There are many types of biofeedback modalities available. One of the most popular and widely accepted modalities is surface EMG biofeedback. EMG (electromyography) bioinstrumentation measures muscle activity by recording electrochemical activity of a muscle occurring during depolarization and recruitment of a skeletal muscle motor unit. This modality is used for muscle reeducation and control when orthopedic injuries or surgeries have taken place, or when the peripheral nervous system has been impaired. It is also used to promote muscle relaxation to decrease muscle guarding, pain, stress, and anxiety.

A simple muscular biofeedback experiment design might use surface EMG electrodes placed over the Vastus Medialis and Vastus Lateralis muscles. Surface EMG electrodes should be placed vertically (parallel to the muscle fibers), over the muscle belly, or largest part of the muscle, and a ground electrode should also be used. Surface EMG should be recorded in several trials, including a Baseline without biofeedback (where the participant is asked to maximally relax, e.g., not contract), Maximal Contraction without Biofeedback, and a variety of Maximal Contraction with Biofeedback, such as visual stimulus or auditory stimulus. After recording, compare the surface EMG recordings and use peak-peak and mean measurements to determine if any significant change was detected between any of the variables.

Biofeedback is considered advantageous, as it provides participants a chance to use their visual and auditory senses to become more aware of how they are performing during therapy or training, attempt to improve upon it, and immediately see the improvement as it is occurring. Because participants can immediately note improvements, they are “rewarded.” This reward will hopefully lead to larger improvements and accomplishments.


MP150 Data Acquisition Software

AcqKnowledge is the next generation in data acquisition and analysis.

With BIOPAC Systems’ MP System and AcqKnowledge acquisition software, research is more efficient than ever. Record, organize, manage and analyze data easily with AcqKnowledge’s intuitive interface and updated features.

The MP150 Data Acquisition System includes:
  •  Ethernet-ready data acquisition and analysis
  • Ability to record multiple channels with differing samples rates
  • Function to record at speeds of up to 400 kHz (aggregate)


AcqKnowledge provides numerous video tutorials which allow you to spend less time learning the software and more time recording and analyzing data. Additionally, the system can be placed in your local area network (LAN), and you can use any PC in the LAN to record from any MP150 system in the network.

AcqKnowledge Benefits and Features

BIOPAC MP150 Systems utilize AcqKnowledge software. Some of the major benefits of AcqKnowledge acquisition software include:

  • Improved lab efficiency
  • Enhanced security and data integrity
  • Configurable user interface
  • Standard Operating Procedure (SOP) template options


    New for AcqKnowledge Version 4.3

    The latest version of AcqKnowledge includes several exciting updates which have made the software even more easy to use than before.

    Focus Areas – This feature simplifies and standardizes data analysis by allowing you to analyze data in selected regions, as well as use it with the most automated analysis routines and the Find Cycle Detector. When you set up focus areas, you can individually label them and search for cycles on these specific regions. The focus areas can then be downloaded into separate spreadsheets. For example, when conducting automated blood pressure analysis, you can download the search baseline, test phase and recovery period focus areas separately.

    Channel Specific Grid Functionality – When using grids within a data file, the grids can be enabled or disabled for different graphs. For instance, if you need a different grid for ECG and Alpha EEG waveform on the same graph, you can adjust and customize each grid. This new tool also allows you to save graph templates and presets for future use.

    Linked Acquisitions – Linked Acquisitions allows you to record from multiple MP150s, MP36Rs, B-Alert Headsets and BioHarness. You can choose from multiple synchronization methods and specify whether or not to create a merged data file at the end of recording. The merged data file then will contain all of your channels of data from each recording, with independent data files for each device.

    Locate Animal ECG Complex Boundaries – This new system locates and marks animal ECG complex boundaries, and functions the same way as the Locate Human ECG Complex Boundaries. However, this feature is optimized for the faster heart rates of small animals. To use the Locate Animal ECG Complex Boundaries, simply enter in the average heart rate for the file, run the routine locater and mark the ECG complex boundaries.

    New Preset Options – Presets help save time on recording and analysis. Rate, expression and box configuration presets are available for both calculation channel set-up and offline analysis. When using this feature, you simply specify the number of horizontal and vertical measurement boxes desired, and then save as a preset for future use.

    New User Interface Features – Version 4.3 includes many new user interface features, including tabbed window display (multiple tabs containing different tab files), textual value toolbar, selection palette enhancements, linked selections, autoscale single waveform, configure number of horizontal measurements, remove annotations from a single channel and journal docking location preference.

    Pressure-Volume Loop Analysis – Baseline analysis is useful for looking at immediate drug delivery effects and when positioning a catheter. The pressure-volume loop analysis feature includes a preconfigured QuickStart template which helps you start recording quickly, and enables you to analyze pressure-volume loops data from anesthetized animals. This tool lets you easily pause recordings and run a quick baseline analysis during use, and features an intuitive loop graph display with a built-in text table.

    Learn More About MP150 Data Acquisition Software

    If you are interested in learning more about how the MP System and AcqKnowledge acquisition software can help you work faster and smarter, please contact BIOPAC Systems.


    BIOPAC is dedicated to developing innovative, high quality and competitively priced life sciences educational and research hardware and software designed to meet customers’ needs.

    Heart Rate Variability

    What is Heart Rate Variability?
    Heart rate variability studies examine alterations in the interval between heart beats. Several physiological variables can affect the normal rhythm of the heart and the interaction between the sympathetic and parasympathetic nervous systems.
    Heart rate fluctuates based on a variety of conditions and can indicate the presence of disease or forewarn impending cardiac diseases. These indicators may always be present but sometimes may only occur occasionally at specific times throughout the day. Heart rate is monitored to assess the health of a subject or the significance of heart abnormalities. Data acquisition of this caliber can have profound advancements in the way heart conditions are understood and treatments are developed.
    Monitoring heart rate variability may be time consuming and difficult without the right tools in place. 
    How heart rate variability works
    The base of your heart rate is located in the sinoatrial (SA) node of the heart. In this node, cells continuously generate an electrical impulse which is spread through the entire heart muscle, causing a contraction. The number of electrical impulses generated per minute is equivalent to the heart beats per minute.
    The autonomic nervous system largely controls the heart rate and rhythm of the heart, and is broken down into two separate areas: the parasympathetic nervous system and the sympathetic nervous system.
    The parasympathetic nervous system affects the heart rate through the release of acetylcholine by the vagus nerve. This can impede activation of SA node activity and may also decrease HRV.
    The sympathetic nervous system impacts the heart rate through a release of epinephrine and norepinephrine. This usually increases activity of the SA node and may increase HRV.

    How BIOPAC fits in
    When performing heart rate variability analysis, the importance of recording proper data can not be overstated.
    "Results reveal that even a single heart period artifact, occurring within a 2-min recording epoch, can lead to errors of estimate heart period variability that are considerably larger than typical effect sizes in psychophysiological studies."
    —Berntson & Stowell, 1998

    AcqKnowledge Electrocardiogram(ECG) Routines

    What is an ECG?
    An ECG - or electrocardiogram – is a common test used to gauge heart health. It monitors the electrical activity of the heart, which can indicate problems related to heart rate and valve health. Other reasons an ECG may be performed are to:
    • Check how the heart responds to exercise (as with a classic treadmill test)
    • See if the walls of the heart chambers are hypertrophied
    • Discover the cause of specific symptoms of heart disease
    • An ECG calculates a wide range of valuable data valuable including:
    • Heart Rate
    • Heart Rhythm
    • Evidence of previous heart attacks
    • Possibility of coronary artery disease
    • Signs of decreased oxygen to the heart


    The main types of ECG are:
    Cardiac stress test - this one is recorded while the subject is active, usually walking on a treadmill or riding on an exercise bike. The typical time for this test is 15-30 minutes.
    Ambulatory - This ECG test is done using a transportable recording device, often called a data logger, that is worn for 24 hours or more, with the subject free to move around in a normal fashion. This type of test is typically used to study infrequent symptoms that might not show up in a resting ECG test. The subject is usually asked to keep track of his/her own symptoms in a journal of some kind, keeping track of the time of each symptom to be later compared to the results of the ECG test.
    Resting - This is the most common ECG test and is taken while the subject is lying down for usually 5-10 minutes. Subjects are instructed to keep as still as possible to avoid other muscle activity interfering with the activity of the heart.
    Some possible limitations of an ECG test include:
    Some irregularity surfacing through the test are false positives, often times not having any medical importance after further assessment is done.
    The test can also show up negative for subjects with some form of heart disease including diagnosed coronary artery disease.

    AcqKnowledge includes the following automated ECG routines, as well as numerous other automated analysis routines and transformation tools:
    Detect and Classify Heartbeats

    Locate Human ECG Complex Boundaries

    Heart Rate Variability



      Personalize your package with specialized amplifiers, leads, electrodes, and/or transducers. Have the ability to record the max of 16 channels of high-fidelity ECG and additional physiological data either wirelessly with BioNomadix or via standard wired amplifiers.

      Contact BIOPAC today for more information.

      Physiological Amplifier Options in Research

      When choosing which physiological amplifier to use in your research, the most important assets typically are accuracy, ease of use and time efficiency.

      BIOPAC’s biopotential amplifiers are not only user friendly and intuitive, but they can also easily be integrated with automatic data acquisition software. When you use AcqKnowledge software with a biopotential amplifier, you can automatically score data and extract measurements on a cycle-by-cycle basis.

      With over 15,000 amplifiers sold for research, BIOPAC is quickly becoming one of the most popular choices for universities.

      How Biopotential Amplifiers Work

      With a wide selection of physiological amplifiers to choose from, creating a system that suits your application requirements is easier than ever.

      The amplifiers are easy to snap together and pull apart for any needed substitutions. BIOPAC’s amplifiers also utilize advanced technology that allows you to use the amplifiers as stand-alone devices with the IPS100C isolated power supply mode.

      To use the biopotential amplifiers, simply connect to unshielded or shielded electrode leads which are terminating with Safelead/Touchproof (1.5 mm) sockets. To increase performance, you can use two shielded electrode leads and one unshielded electrode lead per amplifier.

      For added convenience and ease of use, BIOPAC also provides detailed video tutorials for each of its biopotential amplifiers.

      Physiological Amplifier Types

      BIOPAC offers a wide array of biopotential amplifiers including:

      ECG Electrocardiogram Amplifier – This amplifier records heart generated electrical activity, and can be used to effectively record ECG in humans, animals and isolated organ preparations. When used with the AcqKnowledge data acquisition software, the ECG amplifier will record data and pull out measurements of interest on a cycle-by-cycle basis.

      EEG Electroencephalogram Amplifier – The EEG amplifier shows bioelectric potentials related to neuronal activity of the brain, which is often used in recording unipolar or bipolar EEG measurements. You can use the Alpha detection mode to create a smoothed wave with a peak that indicates maximal alpha activity. Use this amplifier with AcqKnowledge software to automatically filter raw EEG signals and instantly create a full data analysis.

      EGG Electrogastrogram Amplifier – The EGG amplifier amplifies the electric signal which results from activity in the stomach and intestinal smooth muscle. Use the EGG amplifier in conjunction with AcqKnowledge software to automate the EGG gastric wave analysis routine and provide both single and multi-channel recordings.

      EMG Electromyogram Amplifier – Record general and skeletal muscle electrical activity with the EMG amplifier. The fast response amplifier can monitor a single-fiber EMG, motor unit and peripheral nerve action potentials. Much like the other biopotential amplifiers, the EMG amplifier is easily integrated with AcqKnowledge software for performing real-time EMG recording and analysis.

      EOG Electrooculogram Amplifier – The EOG amplifier monitors the DC potential on the skin surrounding the eyes, recording the degree of eye movement in any direction. As it amplifies corneal-retinal potential, the amplifier works with data acquisition software to automatically measure and graph eye movement.

      ERS Evoked Response Amplifier – The evoked response amplifier works by amplifying a small response to a certain stimulus. Because it emits extremely low noise, the amplifier is easily used in applications like auditory brainstem response, startle response, somatosensory evoked response and nerve conduction velocity recording. When used with the AcqKnowledge software, the ERS amplifier automatically generates accurate data recording and analysis.

      Learn More About Biopotential Amplifiers

      If you are interested in learning more about how BIOPAC’s state-of-the-art amplifiers can ease your application process and help you instantly create detailed analytic reports of your data, please contact BIOPAC Systems, Inc. You can also learn about BIOPAC’s extensive collection of transducer amplifiers on the BIOPAC website.



      BIOPAC is dedicated to developing innovative, high quality and competitively priced life sciences educational and research hardware and software designed to meet customers’ needs.

      - Copyright © Life Science Hardware and Software -Metrominimalist- Powered by Blogger - Designed by Johanes Djogan -